Vsam Files In Informatica Certification

Vsam Files In Informatica Certification Average ratng: 9,5/10 2212votes
Vsam Files In Informatica Certification

Maximize Your Mainframe Data Integration Investment Without Mainframe-Specific Skills Informatica's mainframe data integration solutions are designed to interoperate seamlessly with Informatica PowerCenter and Informatica PowerExchange on Linux, UNIX, and Windows platforms. These solutions provide flexible, scalable data transformation and data access capabilities on your mainframe and on commodity servers. • Informatica PowerCenter for z/Linux. Run secure CPU-intensive transformations at full speed, with complete access to the entire range of sources and targets supported by PowerExchange, wherever data resides.

Informatica PowerExchange for VSAM On-demand Access to Enterprise Data. Contained in VSAM and sequential files or for use throughout the organization.

• PowerCenter for Linux, UNIX, or Windows. Access mainframe data completely and securely with the encrypted communication in PowerCenter as well as PowerExchange's adherence to all access controls established by SAF and the data source. • PowerExchange for z/OS and z/Linux. Access mainframe data in multiple formats and any supported environment, quickly and securely, without queuing or staging tables. • PowerExchange Change Data Capture Option. Lower your MIPS usage and manage costs by sending captured mainframe data to PowerCenter running on z/Linux or any other supported PowerCenter environment.

Balance Security, Performance, and Cost with Mainframe Data Integration Informatica's mainframe data integration solutions enable you to configure a highly scalable, real-time data integration environment that extends the value of your existing mainframe and the data it contains. These solutions help you balance security, performance, and cost according to your own requirements. Maintain data security through access controls, encryption, and virtualized network technology, whether you access mainframe data in the mainframe environment or via Linux, UNIX, or Windows.

Matteo Tarantino Disco Grafia. • Performance. Access mainframe data directly and at full speed from any source or target supported by PowerExchange, whether it's in files, relational databases, or prerelational databases. Lower MIPS-based costs, save development time, and decrease total cost of ownership by deferring upgrades to your mainframe environment.

Integrate Data from Multiple Mainframe Sources and Targets Informatica's mainframe data migration solutions support a broad variety of common mainframe sources and targets so you can integrate mainframe data and deliver it to the right place, at the right time, in the right format. • z/OS Adabas Binary flat files Datacom DB2 for z/OS IDMS IMS DB Teradata VSAM WebSphere MQ • z/Linux Binary flat files DB2 for Linux Oracle WebSphere MQ.

Toolbox informatica-lNot clear how you have created the VSAM source, but if you manually create a cobol copybook with repeating the occurs columns and then import it to Infa sources. This will read the data as 11, f1,f2,f3,f4.f9, C1,c2.c5, xyz. If you did not expand the occurs in.cbl, Infa will create a separate target for each occurs clause. Thanks -Vijay From: karthikeya g via informatica-l Sent: Tuesday, April 21, 2009 4:33 AM To: Vijay ja Subject: [informatica-l] Working with VSAM files as Source in Informatica? Hi, Whilw we are working with VSAM Sources in Informatica, As the souce file conatins multiple occurrences for different fileds (for eg field1 conatisn 9 occurs, field2 contains 5 occurs) the mapping becomes in valid? Can anybody give me a suggession how to deal with the above scenario?